Medical Grade Nitrous Oxide (N2O) Gas Cylinder – Pin-Index Valve Cylinder for Hospital & Dental Use
Medical Grade Nitrous Oxide (N2O) Gas Cylinder – Pin-Index Valve Cylinder for Hospital & Dental Use

Medical Grade Nitrous Oxide (N2O) Gas Cylinder – Pin-Index Valve Cylinder for Hospital & Dental Use

(0 reviewPlural)

৳ 17,000.00

৳ 18,000.00

Save 6%
!
Select of this product.
QuantityinStock
SUB_CATEGORYNitrous Oxide
CHILD_CATEGORYN2O Cylinder Refill
SKUAME-GAS-N2O-001
Tags
Best Sale ProductsFlash Deals

Description

Medical Grade Nitrous Oxide (N2O) Gas Cylinder – For Hospitals, Operation Theatres and Dental Clinics in Bangladesh

Nitrous oxide is one of the oldest and best-known gases in clinical practice. In hospitals and dental clinics it is used for short-term pain relief and light sedation, and in operation theatres it is used as a component of general anaesthesia, always in combination with oxygen and always under the control of trained staff. Advanced Medical Equipment supplies medical grade nitrous oxide (N2O) cylinders to licensed healthcare facilities in Bangladesh, together with clear information on cylinder types, safe handling and correct use.

Important notice: this product is for professional healthcare use only. It is not a consumer product, it is not for recreational use and it must never be inhaled directly from a cylinder. Medical nitrous oxide must be administered only through suitable medical equipment by qualified personnel.

What Is Medical Nitrous Oxide?

Nitrous oxide (chemical formula N2O, CAS number 10024-97-2) is a colourless gas with a faint sweetish smell. It is stored in steel cylinders as a liquefied compressed gas. Medical-grade nitrous oxide is produced to a pharmaceutical purity standard and filled into cylinders that are cleaned, tested and fitted with the correct medical valve. This is quite different from nitrous oxide sold for engines, which is not intended for human use and may contain additives. The cylinders and gas offered here are intended solely for clinical settings.

Clinical Uses

  • Operation theatres: nitrous oxide is commonly used in combination with oxygen and other anaesthetic agents as part of balanced general anaesthesia, administered through an anaesthesia machine.
  • Dental practice: with an appropriate nitrous oxide/oxygen delivery system, it is used for mild sedation and anxiety relief during dental treatment, including for nervous adults and children, according to the clinician's judgement and training.
  • Analgesia in selected settings: nitrous oxide–oxygen mixtures are used for short-term pain relief in some obstetric and procedural settings, where the facility has proper equipment and protocols.

The clinician decides whether nitrous oxide is suitable for a patient, based on their medical history and the procedure. Certain conditions – for example, some chest, ear or bowel conditions where trapped gas is a risk, vitamin B12 deficiency, or certain pregnancies – may require special caution or avoidance.

Key Features of the Cylinder Supply

  • Medical grade gas: supplied for clinical use, typically with a purity of about 99.0–99.5%; request the supplier's certificate of analysis with your order.
  • Standard medical cylinder sizes: commonly available in A type (5 litre water capacity), B type (10 litre) and D type (47 litre) steel cylinders. Tell us your usage and we will recommend a size.
  • Pin-index valve system: medical cylinders use a pin-index arrangement so that the cylinder can only be connected to the correct gas yoke, reducing the risk of connecting the wrong gas.
  • Liquefied gas storage: nitrous oxide is stored as a liquid under pressure, meaning a relatively small cylinder holds a large volume of gas.
  • Refilling and exchange options: we can advise on refilling or exchange arrangements for your cylinders in line with applicable regulations.
  • Nationwide supply: we supply hospitals, clinics and dental chambers across Dhaka, Chattogram, Sylhet, Rajshahi, Khulna and other cities, subject to cylinder transport rules.

Medical Nitrous Oxide vs Automotive Nitrous

Medical nitrous oxide cylinders differ from automotive or racing nitrous bottles in their valve type, labelling, gas purity, testing and intended use. Automotive products are not made for human inhalation and must never be used for medical purposes. When you order from us, please confirm the cylinder type, size, label and valve with our team so that you receive a cylinder suitable for clinical equipment.

Who Should Buy Medical Nitrous Oxide?

  • Private and government hospitals with anaesthesia machines
  • Day-surgery and specialist centres
  • Dental clinics offering inhalation sedation with the correct equipment and trained staff
  • Maternity and obstetric units with approved analgesia protocols
  • Medical colleges and teaching facilities

Equipment Needed to Use Nitrous Oxide Safely

A cylinder alone is not a complete system. For safe delivery you will need:

  • A properly maintained anaesthesia machine or a dedicated nitrous oxide/oxygen sedation unit that includes flow meters and an oxygen-failure safety mechanism
  • A pressure regulator and correct gas yoke or hose compatible with the pin-index valve
  • A scavenging system to remove exhaled and waste gas from the room, which protects staff from chronic exposure
  • Good ventilation in the treatment room
  • Monitoring equipment appropriate to the procedure, such as a pulse oximeter
  • Oxygen supply and resuscitation equipment on standby

Safe Storage and Handling

Nitrous oxide is not flammable by itself, but it is an oxidiser that supports combustion, and the cylinder is a high-pressure container. Treat it with the same respect as any medical gas cylinder.

  • Store cylinders upright, secured with a chain or stand, in a cool, dry, well-ventilated place away from direct sunlight, heat sources and flammable materials.
  • Keep valve protection caps on when the cylinder is not in use.
  • Never use oil, grease or petroleum products on valves, regulators or fittings.
  • Open the valve slowly and only with the proper key or hand-wheel; do not force damaged threads.
  • Move cylinders on a trolley rather than rolling or dragging them, and never drop them.
  • Close the cylinder valve after each session and when the cylinder is empty.
  • Check for leaks with approved methods and replace damaged seals promptly.
  • Keep stock rotated and make sure that staff are trained in cylinder handling and emergency procedures.

Because nitrous oxide cools rapidly as it expands, valves and regulators can become very cold during heavy use; avoid touching cold metal with bare skin.

Occupational Safety for Staff

Repeated exposure to waste anaesthetic gas in poorly ventilated rooms is a recognised occupational concern for clinic staff. Using a scavenging system, keeping connections tight, maintaining equipment regularly and ventilating the room all help reduce exposure. Pregnant staff members should follow the guidance of their occupational health adviser.

Compliance and Responsible Supply

Medical gases are regulated products. Healthcare facilities are responsible for storing, handling and using them in line with the rules that apply in Bangladesh and with their own clinical governance. We supply this product for legitimate medical and dental use and may ask for facility details before confirming an order. We cannot supply nitrous oxide for recreational or non-medical purposes.

Why Buy from Advanced Medical Equipment?

We specialise in hospital and clinic equipment, and we can supply the surrounding items you need: oxygen concentrators, oxygen cylinders, regulators and flow meters, patient monitoring devices and emergency equipment. This lets you equip a treatment room from a single, knowledgeable supplier. We provide transparent pricing, practical safety guidance and support with ordering, refilling and delivery logistics.

Frequently Asked Questions

Is this product for personal or recreational use?

No. It is strictly for professional medical and dental use by trained staff using suitable equipment.

What cylinder sizes are available?

Medical nitrous oxide is commonly supplied in A (5 L), B (10 L) and D (47 L) steel cylinders. Contact us for availability of the size you need.

Can I use it with a normal oxygen regulator?

No. Each medical gas has its own regulator, yoke and valve connection. Use only equipment designed for nitrous oxide.

Do you refill empty cylinders?

Please call us to discuss refilling and exchange options available for your cylinder type.

What documents can I request?

You can ask for the gas purity certificate and cylinder details with your order.

Does it need special transport?

Yes. Gas cylinders must be transported upright, secured and ventilated, in accordance with applicable rules.

Order Medical Nitrous Oxide

Hospitals and clinics can call or WhatsApp 01718-528863 to confirm stock, cylinder size, documentation and delivery arrangements.

Additional Information

Product TypeMedical Gas Cylinder – Nitrous Oxide Chemical Name and Formula

reviewPlural (0)

0/5

(0 reviewPlural)

(0)
(0)
(0)
(0)
(0)